#9300 Echinococcus multilocularis (Em2-Em18) IgG ELISA
ELISA kit for the diagnosis of alveolar echinococcosis in humans

Lot 2232M

Results of quality control

Kit: Bordier Affinity Products SA, Echinococcus multilocularis (Em2-Em18) IgG ELISA, Article 9300
Expiry date: 16.06.2024, Control date: 11.10.2023,  Control #  3

No serum blank (average) : 0.136

Sample

Absorbances of individual wells after blank reduction

Average

% pos.

No serum blank
-0.010 -0.033 -0.012 -0.012 0.000 0
Negative control serum
(N° 9300-06)
0.060 0.058 0.020 0.036 0.043 2
Weak positive serum
(N° 9300-07)
0.765 0.804 0.727 0.699 0.748 31
Positive control serum
(N° 9300-08)
2.262 2.474 2.380 2.392 2.377 100

Validation criteria:

  Criterion Measure Valid
Absorbance of positive serum 9300-08 > 1.200 2.377 Yes
Absorbance of negative serum 9300-06, as % of positive serum < 12 % 2 % Yes
Absorbance of no serum blank < 0.350 0.136 Yes

Comments:

Good for use.

Bordier Affinity Products SA, Chatanerie 2, Bātiment Biokema, CH-1023 Crissier, Switzerland