Home    Products    Sales Conditions & distributors    Quality controls    Instructions For Use    Links

#9450 Strongyloïdes ratti
ELISA kit for the diagnosis of human strongyloidosis

Lot 2015S

Results of quality control

Kit: Bordier Affinity Products SA, Strongyloides ratti ELISA. Article 9450.
Expiry date: 07.02.2022, Control date: 04.12.2020,  Control #  2

No serum blank (average) : 0.126

Sample

Absorbances of individual wells after blank reduction

Average

% pos.

No serum blank
-0.004 0.002 0.002 0.000 0.000 0
Negative control serum
(N° 9450-06)
0.035 0.055 0.046 0.057 0.048 3
Weak positive serum
(N° 9450-07)
0.570 0.597 0.556 0.573 0.574 30
Positive control serum
(N° 9450-08)
1.880 1.924 1.902 1.896 1.901 100

Validation criteria:

  Criterion Measure Valid
Absorbance of positive serum 9450-08 > 1.200 1.901 Yes
Absorbance of negative serum 9450-06, as % of positive serum < 12 % 3 % Yes
Absorbance of no serum blank < 0.350 0.126 Yes

Comments:

Good for use.

Bordier Affinity Products SA, Chatanerie 2, Bâtiment Biokema, CH-1023 Crissier, Switzerland
Phone: + 41 21 633 31 67.  Fax: + 41 21 633 31 78. Email: cb(at)bordier.ch